Membrane structure is a control function is very necessary, in particular in some field membrane structure, the stadium membrane structure, membrane structure, pitch square membrane structure, stage of membrane structure, etc. Membrane structure is the realization of the function of anti noise through acoustic design centered around two aspects of membrane structure acoustic quality.


First, how is shielding external noise is the impact on the building;


Second, the building outline of effects and the reverberation time of the echo. Noise and echo very different factors to consider, but they must be considered at the same time, the well building acoustic environmental quality of comprehensive evaluation.


A, internal echo


The echo time is proportional to the interior of the building volume is, with the inner surface is inversely proportional to the absorption rate. Good voice quality requirement is the echo time is short, so as to avoid mutual interference between the crossing, it's difficult for small meeting room does not generally, but large closure construction space is very difficult to solve this problem effectively, such as gym, indoor track and field, water sports center, stadium, etc.


According to the overall planning, function of architecture design, economic budget, choose the optimal ratio of membrane to design plan:


1, double membrane. PVC film and PVC lining, PTFE plus PVC lining, PTFE membrane and outer membrane PTFE lining, lined with membrane absorption index, main control outer membrane is given priority to with architectural, structural durability.


2, double membrane and sound insulation layer. Pay attention to the sound insulation material and heat insulation heat preservation material compatibility, and the coordination with light transmittance.


3, PTFE, PVC single layer film.


Second, the external noise isolation


First consider of the front of membrane structure and location, so that to reduce the noise big infiltration. In addition to the location of the building design of acoustic facilities should also be considered, in order to reduce the common ground transmission noise, and the noise source and the structure. In general, the distance between the source and buildings each doubled, noise reduction 6 dB, and the use of brush noise barrier can reduce 0.4 dB, and can be neglected.


Increase of the membrane layer, interlayer thickness control arrow and, if necessary on the membrane layer is to improve the effect of noise reduction method available. Need to carefully consider the connection technology of membrane structure, to ensure its impermeability, reducing the noise of the spreads through the air from the possibility of a crack in the infiltration. To ensure that when these measures should not be at the same time make the structure of the thermal performance is affected.


Like most of the architectural acoustics processing, supporting facilities and other noise source of a noise from the conclusion is very important. Serious indoor acoustic surface design is also very important, because the sound absorption technology helps to dampen the effects of indoor background noise.


Key words:
Relevant information

Service Hotline0755 27809070

Shenzhen: 2nd floor Huizhou, Baoan Xixiang Baoyunda Logistics Research and Development Center, Shenzhen: 8th floor, Block B, Jinhaoyuan Building, Huiyang District, Huizhou City, Guangdong Province
Email: folan@sz1680.com
Copyright 2018 Shenzhen Folan Space Membrane Structure Co., Ltd. all rights reserved.
Guangdong ICP prepare No. 18128411 -1
Technical support: 國人在線 Disclaimer Website map

WeChat 2D code

主站蜘蛛池模板: 乌拉特后旗| 吴忠市| 安陆市| 文昌市| 九寨沟县| 鄱阳县| 昌图县| 治多县| 尚义县| 金坛市| 浦东新区| 麻阳| 抚州市| 阿拉善左旗| 亳州市| 克拉玛依市| 若尔盖县| 甘谷县| 石台县| 嵊州市| 安西县| 阿拉尔市| 牙克石市| 海兴县| 西昌市| 兖州市| 阿鲁科尔沁旗| 九江市| 孝义市| 客服| 乌什县| 阳东县| 太仆寺旗| 白沙| 航空| 满城县| 潞城市| 沂源县| 崇阳县| 东源县| 铜山县|